6BVV
Nipah virus W protein C-terminus in complex with Importin alpha 3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-03-01 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 47.701, 65.610, 73.939 |
Unit cell angles | 90.00, 99.79, 90.00 |
Refinement procedure
Resolution | 38.211 - 2.300 |
R-factor | 0.2006 |
Rwork | 0.199 |
R-free | 0.22240 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.747 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.211 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rpim | 0.087 | 0.274 |
Number of reflections | 19881 | 1953 |
<I/σ(I)> | 8.6 | 3.5 |
Completeness [%] | 98.9 | 99.2 |
Redundancy | 2.3 | 2.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2 M lithium nitrate, 20% w/v PEG3350 |