5YEM
CATPO mutant - T188F
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID29 |
Synchrotron site | ESRF |
Beamline | ID29 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-06-25 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97241 |
Spacegroup name | I 1 2 1 |
Unit cell lengths | 125.109, 121.539, 186.025 |
Unit cell angles | 90.00, 101.82, 90.00 |
Refinement procedure
Resolution | 112.890 - 1.490 |
R-factor | 0.1596 |
Rwork | 0.158 |
R-free | 0.18740 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4aum |
RMSD bond length | 0.023 |
RMSD bond angle | 2.016 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 112.890 | 1.510 |
High resolution limit [Å] | 1.490 | 1.490 |
Rmerge | 0.812 | |
Number of reflections | 440118 | |
<I/σ(I)> | 7.4 | 1.4 |
Completeness [%] | 99.3 | 94.4 |
Redundancy | 3.4 | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | PEG400, Potassium chloride, Calcium chloride, Sodium cacodylate |