Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5N6P

AMPA receptor NTD mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyCCD
Collection date2010-11-29
DetectorADSC QUANTUM 315
Wavelength(s)0.9393
Spacegroup nameP 41 21 2
Unit cell lengths94.500, 94.500, 160.570
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution32.710 - 2.800
R-factor0.20817
Rwork0.206
R-free0.24933
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3hsy
RMSD bond length0.016
RMSD bond angle1.750
Data reduction softwareiMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]32.7102.950
High resolution limit [Å]2.8002.800
Rmerge0.1190.846
Rpim0.0690.483
Number of reflections184942683
<I/σ(I)>9.41.9
Completeness [%]99.6100
Redundancy3.94
CC(1/2)0.9930.498
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.629116-20% PEG3350, 200 mM sodium formate

220113

PDB entries from 2024-05-22

PDB statisticsPDBj update infoContact PDBjnumon