Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5N2W

WT-Parkin and pUB complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2015-10-04
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9795
Spacegroup nameP 63 2 2
Unit cell lengths147.290, 147.290, 87.490
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution56.340 - 2.680
R-factor0.201
Rwork0.198
R-free0.24300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5c1z 5caw
RMSD bond length0.009
RMSD bond angle1.140
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.3402.810
High resolution limit [Å]2.6802.680
Rmerge0.1070.719
Number of reflections15028
<I/σ(I)>8.91.9
Completeness [%]93.693.7
Redundancy4.64.2
CC(1/2)0.670
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP277100mM Tris pH 8.5, 200mM TMAO, PEG MME 2000

218853

PDB entries from 2024-04-24