5LMH

High dose Thaumatin - 160-200 ms.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P14 (MX2)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP14 (MX2)
Temperature [K]296
Detector technologyPIXEL
Collection date2015-10-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.96863
Spacegroup nameP 41 21 2
Unit cell lengths58.480, 58.480, 151.730
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.950 - 1.960
R-factor0.1808
Rwork0.179
R-free0.22300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1lr2
RMSD bond length0.015
RMSD bond angle1.691
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0151)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.9502.030
High resolution limit [Å]1.9601.960
Rmerge0.1430.663
Number of reflections18364
<I/σ(I)>5.81.9
Completeness [%]93.193.4
Redundancy3.23.3
CC(1/2)0.9860.650
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5296.3 M sodium tartrate and 50 mM Tris, pH 6.8

221051