5HEH

Pentameric ligand-gated ion channel GLIC mutant P246A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2012-02-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9197
Spacegroup nameC 1 2 1
Unit cell lengths177.690, 133.940, 159.830
Unit cell angles90.00, 101.10, 90.00
Refinement procedure
Resolution29.913 - 3.300
R-factor0.2457
Rwork0.244
R-free0.28030
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ehz
RMSD bond length0.003
RMSD bond angle0.654
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.400
High resolution limit [Å]3.3003.300
Rmerge0.1010.773
Number of reflections55197
<I/σ(I)>13.12.4
Completeness [%]99.699.6
Redundancy5.35.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4277PEG 4000, Ammonium Sulfate

219869

PDB entries from 2024-05-15