Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5HCT

Endothiapepsin in complex with biacylhydrazone

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyCCD
Collection date2015-02-08
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 1 21 1
Unit cell lengths45.234, 72.822, 52.704
Unit cell angles90.00, 108.91, 90.00
Refinement procedure
Resolution42.790 - 1.360
R-factor0.1225
Rwork0.121
R-free0.15000
RMSD bond length0.007
RMSD bond angle1.176
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1492)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.7901.440
High resolution limit [Å]1.3601.360
Rmerge0.491
Number of reflections69237
<I/σ(I)>11.272.41
Completeness [%]99.698.8
Redundancy3.773.63
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000; crystals obtained by streak-seeding

218853

PDB entries from 2024-04-24