Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5FC6

Murine SMPDL3A in complex with ADP analog AMPCP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2015-01-21
DetectorRAYONIX MX-300
Wavelength(s)0.97949
Spacegroup nameC 2 2 21
Unit cell lengths124.351, 132.888, 80.519
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.399 - 1.658
R-factor0.1625
Rwork0.161
R-free0.19070
RMSD bond length0.011
RMSD bond angle1.083
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 Overall
Low resolution limit [Å]45.400
High resolution limit [Å]1.658
Number of reflections78590
<I/σ(I)>15.8
Completeness [%]99.6
Redundancy7.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293citrate, PEG

219869

PDB entries from 2024-05-15