5FC6
Murine SMPDL3A in complex with ADP analog AMPCP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-01-21 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97949 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 124.351, 132.888, 80.519 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.399 - 1.658 |
R-factor | 0.1625 |
Rwork | 0.161 |
R-free | 0.19070 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.083 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 45.400 |
High resolution limit [Å] | 1.658 |
Number of reflections | 78590 |
<I/σ(I)> | 15.8 |
Completeness [%] | 99.6 |
Redundancy | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | citrate, PEG |