5ELI
Triggering receptor expressed on myeloid cells 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-07-01 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.979180 |
Spacegroup name | P 64 2 2 |
Unit cell lengths | 125.763, 125.763, 183.659 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 40.689 - 3.098 |
R-factor | 0.2611 |
Rwork | 0.261 |
R-free | 0.27360 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1u9k |
RMSD bond length | 0.006 |
RMSD bond angle | 1.181 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.210 |
High resolution limit [Å] | 3.098 | 3.098 |
Rmerge | 0.109 | 0.800 |
Number of reflections | 16285 | |
<I/σ(I)> | 20.96 | 1.72 |
Completeness [%] | 99.9 | 100 |
Redundancy | 12.9 | 13.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.1 | 290 | 2 M NaCl, 0.2 M MgCl2, 0.2 M NDSB 201, 100 mM HEPES pH 7.1 |