Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4X39

Gallus interleukin-1 beta mutant - T117A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE BL13B1
Synchrotron siteNSRRC
BeamlineBL13B1
Temperature [K]100
Detector technologyCCD
Collection date2014-11-04
DetectorADSC QUANTUM 315r
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths35.613, 38.509, 102.040
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.160 - 1.610
R-factor0.2023
Rwork0.200
R-free0.23655
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2wry
RMSD bond length0.015
RMSD bond angle1.762
Data scaling softwareDENZO (HKL-2000)
Refinement softwareREFMAC (5.7.0032)
Data quality characteristics
 Overall
Low resolution limit [Å]26.160
High resolution limit [Å]1.600
Number of reflections19075
<I/σ(I)>39.14
Completeness [%]99.7
Redundancy6.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2931.15 M (NH4)2SO4, 0.1 M Tris, 0.2 M LiSO4

219515

PDB entries from 2024-05-08

PDB statisticsPDBj update infoContact PDBjnumon