Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-12-04 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 209.530, 447.030, 622.750 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | ? - 3.100 |
Rwork | 0.252 |
R-free | 0.30200 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB Entries: 2j00 2j01 |
RMSD bond length | 0.020 |
RMSD bond angle | 1.280 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 3.180 | |
High resolution limit [Å] | 3.100 | 3.100 |
Rmerge | 0.258 | 0.012 |
Number of reflections | 989777 | 38341 |
<I/σ(I)> | 0.8 | |
Completeness [%] | 92.2 | 49.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.6 | 292 | 0.1-0.2 M Arginine-HCL, 0.1 M Tris pH 7.6, 2.5 % Peg 20K, 7-12% MPD, 0.5 mM BME, vapor diffusion, temperature 292K |