Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4PKD

U1-70k in complex with U1 snRNA stem-loops 1 and U1-A RRM in complex with stem-loop 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2011-10-22
DetectorPSI PILATUS 6M
Wavelength(s)1.0332
Spacegroup nameC 1 2 1
Unit cell lengths80.220, 66.600, 93.730
Unit cell angles90.00, 110.95, 90.00
Refinement procedure
Resolution87.000 - 2.500
R-factor0.19992
Rwork0.197
R-free0.25791
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1urn
RMSD bond length0.019
RMSD bond angle1.910
Refinement softwareREFMAC (5.8.0071)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]87.5402.640
High resolution limit [Å]2.5002.500
Rmerge0.0760.350
Number of reflections15967
<I/σ(I)>113.2
Completeness [%]99.199.4
Redundancy3.73.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.229340% MPD, 0.15 M sodium chloride, 0.1 M sodium acetate, pH 4.2

219140

PDB entries from 2024-05-01