Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4MGK

Selective activation of Epac1 and Epac2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-1
Synchrotron siteESRF
BeamlineID14-1
Temperature [K]100
Detector technologyCCD
Collection date2009-06-13
DetectorADSC QUANTUM 315r
Wavelength(s)0.972
Spacegroup nameI 21 21 21
Unit cell lengths125.040, 144.550, 227.840
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.900 - 2.700
R-factor0.24995
Rwork0.249
R-free0.26441
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3cf6
RMSD bond length0.006
RMSD bond angle0.942
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.800
High resolution limit [Å]2.7002.700
Number of reflections56554
<I/σ(I)>3.03
Completeness [%]99.399.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.62770.4M (NH4)2SO4, 1.2M LI2SO4, 0.1M CITRATE, pH 5.6, VAPOR DIFFUSION, SITTING DROP, temperature 277K

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon