4LCI
Anti canine CD28 antibody, 1C6
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-03 |
Detector | ADSC QUANTUM 315r |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 44.599, 71.621, 73.234 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.600 - 1.900 |
R-factor | 0.18157 |
Rwork | 0.179 |
R-free | 0.23038 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1h8n |
RMSD bond length | 0.015 |
RMSD bond angle | 1.584 |
Data reduction software | d*TREK |
Data scaling software | d*TREK |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.600 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.255 | |
Number of reflections | 18024 | |
<I/σ(I)> | 4.1 | |
Completeness [%] | 91.1 | 94.99 |
Redundancy | 1.38 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 3.5M Sodium formate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |