Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4HH9

Anti-Human Cytomegalovirus (HCMV) Fab KE5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]110
Detector technologyCCD
Collection date2012-09-28
DetectorRAYONIX MX300HE
Wavelength(s)1.03320
Spacegroup nameP 1 21 1
Unit cell lengths73.860, 79.470, 86.270
Unit cell angles90.00, 113.25, 90.00
Refinement procedure
Resolution43.000 - 1.700
R-factor0.217
Rwork0.217
R-free0.22400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3eyf
RMSD bond length0.004
RMSD bond angle1.361
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.0001.750
High resolution limit [Å]1.7001.700
Rmerge0.0760.512
Number of reflections97584
<I/σ(I)>19.043.8
Completeness [%]96.895.5
Redundancy7.337.37
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.52980.05M Bis-Tris, pH 5.5, 20% PEG 3350, 0.2M Ammonium citrate, VAPOR DIFFUSION, HANGING DROP, temperature 298K

220472

PDB entries from 2024-05-29

PDB statisticsPDBj update infoContact PDBjnumon