4E40
The haptoglobin-hemoglobin receptor of Trypanosoma congolense
Experimental procedure
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-10-21 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.916 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 104.530, 104.530, 113.070 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 90.530 - 1.600 |
R-factor | 0.20677 |
Rwork | 0.206 |
R-free | 0.22332 |
Structure solution method | MIR |
RMSD bond length | 0.018 |
RMSD bond angle | 1.818 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | SHARP |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 90.530 |
High resolution limit [Å] | 1.600 |
Number of reflections | 46112 |
Completeness [%] | 100.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 288 | 5% PEG 12,000, 0.1M sodium acetate pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 288K |