3EQ0
Thrombin Inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 110 |
Detector technology | CCD |
Collection date | 2008-05-03 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 0.91841 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 70.100, 71.400, 72.400 |
Unit cell angles | 90.00, 100.40, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.530 |
R-factor | 0.1979 |
Rwork | 0.196 |
R-free | 0.24890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1h8d |
RMSD bond length | 0.010 |
RMSD bond angle | 0.028 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHELX |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.560 |
High resolution limit [Å] | 1.530 | 1.530 |
Number of reflections | 49919 | |
<I/σ(I)> | 26.58 | 2.14 |
Completeness [%] | 94.5 | 97.9 |
Redundancy | 2.5 | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | Phosphate Buffer, Sodium Chloride, PEG 8000, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |