2AXU
Structure of PrgX
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-03-03 |
Wavelength(s) | 0.97940 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 92.654, 134.718, 195.930 |
Unit cell angles | 90.00, 100.30, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.900 |
R-factor | 0.201 |
Rwork | 0.199 |
R-free | 0.26600 |
Structure solution method | ISO to Y153C |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 15.000 |
High resolution limit [Å] | 2.900 |
Number of reflections | 104010 |
Completeness [%] | 99.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5 | 298 | PEG 4000, citrate-phophate , pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |