1YVR

Ro autoantigen

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X25
Synchrotron siteNSLS
BeamlineX25
Temperature [K]113
Detector technologyCCD
Collection date2004-08-28
Spacegroup nameP 21 21 21
Unit cell lengths68.780, 91.750, 93.880
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 1.950
R-factor0.2131
Rwork0.213
R-free0.25700
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.335
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.030
High resolution limit [Å]1.9401.940
Number of reflections41498
Completeness [%]94.398.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5298PEG 4000, sodium formate, NaH2PO4, Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K