Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1RYW

C115S MurA liganded with reaction products

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU300
Temperature [K]85
Detector technologyIMAGE PLATE
Collection date2000-06-14
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths80.867, 153.729, 135.089
Unit cell angles90.00, 104.17, 90.00
Refinement procedure
Resolution20.000 - 2.300
R-factor0.178
Rwork0.178
R-free0.22500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ejc
RMSD bond length0.007
RMSD bond angle1.320
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.340
High resolution limit [Å]2.3002.300
Number of reflections140111
<I/σ(I)>123
Completeness [%]98.997.3
Redundancy64
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5292PEG 20,000, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon