Loading
PDBj
メニューPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9GT4

DTPAA CHIP EXPERIMENT, ID29, X,Y SPACING 25,75

9GT4 の概要
エントリーDOI10.2210/pdb9gt4/pdb
分子名称Deferrochelatase, PROTOPORPHYRIN IX CONTAINING FE (3 entities in total)
機能のキーワードperoxidase, radiation damage, serial crystallography, oxidoreductase
由来する生物種Streptomyces lividans 1326
タンパク質・核酸の鎖数2
化学式量合計79891.11
構造登録者
Gorel, A.,Schlichting, I. (登録日: 2024-09-17, 公開日: 2025-10-08, 最終更新日: 2026-04-22)
主引用文献Gorel, A.,Shoeman, R.L.,Hartmann, E.,Nizinski, S.,Appleby, M.V.,Beale, E.V.,Dworkowski, F.,Gotthard, G.C.,Beale, J.H.,Holton, J.,Doak, R.B.,Barends, T.R.M.,Schlichting, I.
Testing the limits: serial crystallography using unpatterned fixed targets.
Iucrj, 12:692-709, 2025
Cited by
PubMed Abstract: Sheet-on-sheet (SOS) fixed-target chips are arguably the most versatile, cheapest and simplest sample-delivery method for ambient-temperature data acquisition using serial crystallography approaches at synchrotrons and X-ray free-electron lasers (XFELs). Their defining feature, the absence of any hard-patterned restrictions around crystals, is their strength as it removes limitations on crystal sizes or environments. However, it is also their weakness when it comes to limiting undesired effects on yet-to-be-irradiated crystals due to diffusing heat, radicals or gas originating from previous exposures. We explored whether SOS chips can be used for damage-free serial data collection on the new ID29 beamline at the ESRF-EBS, a fourth-generation synchrotron light source, as well as at the new Cristallina-MX station at SwissFEL. We collected serial data sets from microcrystals of the hemoprotein DtpAa, which was reported to have a highly radiation-sensitive iron-water bond length. The data sets differ in step size between exposures within and between lines of a serpentine-like data-acquisition scan. We observe no significant changes in the distance of the water ligand of the heme in the structures obtained from the ID29 SSX data. However, when compared with those collected at Cristallina-MX, the diffraction intensities collected at ID29 suggest global damage akin to Bragg termination occurring during the 90 µs exposure at ID29. Moreover, differences in the heme geometry and the proximal histidine-iron bond length point to local damage in all ID29 data sets regardless of the X-ray spacing. SFX data collected at Cristallina-MX show a phase transition of the DtpAa crystal lattice for X-ray step sizes of ≤20 µm. This phase transition might be caused by heating and/or hydrogen-gas-induced crystal dehydration. Vigilance remains required to safeguard against radiation damage at fourth-generation synchrotrons and XFELs.
PubMed: 41081786
DOI: 10.1107/S2052252525008371
主引用文献が同じPDBエントリー
実験手法
X-RAY DIFFRACTION (1.67 Å)
構造検証レポート
Validation report summary of 9gt4
検証レポート(詳細版)ダウンロードをダウンロード

252456

件を2026-04-22に公開中

PDB statisticsPDBj update infoContact PDBjnumon