Loading
PDBj
メニューPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

7PVC

The structure of Kbp.K from E. coli with potassium bound.

5FIM」から置き換えられました
7PVC の概要
エントリーDOI10.2210/pdb7pvc/pdb
NMR情報BMRB: 25839
分子名称Potassium binding protein Kbp, POTASSIUM ION (2 entities in total)
機能のキーワードpotassium ion binding metal ion binding response to potassium ion response to stimulus cytoplasm, metal binding protein
由来する生物種Escherichia coli (strain K12)
タンパク質・核酸の鎖数1
化学式量合計17193.33
構造登録者
Smith, B.O. (登録日: 2021-10-01, 公開日: 2021-10-13, 最終更新日: 2023-10-11)
主引用文献Torres Caban, C.C.,Yang, M.,Lai, C.,Yang, L.,Subach, F.V.,Smith, B.O.,Piatkevich, K.D.,Boyden, E.S.
Tuning the Sensitivity of Genetically Encoded Fluorescent Potassium Indicators through Structure-Guided and Genome Mining Strategies.
ACS Sens, 7:1336-1346, 2022
Cited by
PubMed Abstract: Genetically encoded potassium indicators lack optimal binding affinity for monitoring intracellular dynamics in mammalian cells. Through structure-guided design and genome mining of potassium binding proteins, we developed green fluorescent potassium indicators with a broad range of binding affinities. KRaION1 (K ratiometric indicator for optical imaging based on mNeonGreen 1), based on the insertion of a potassium binding protein, Kbp, from (Ec-Kbp) into the fluorescent protein mNeonGreen, exhibits an isotonically measured of 69 ± 10 mM (mean ± standard deviation used throughout). We identified Ec-Kbp's binding site using NMR spectroscopy to detect protein-thallium scalar couplings and refined the structure of Ec-Kbp in its potassium-bound state. Guided by this structure, we modified KRaION1, yielding KRaION1/D9N and KRaION2, which exhibit isotonically measured 's of 138 ± 21 and 96 ± 9 mM. We identified four Ec-Kbp homologues as potassium binding proteins, which yielded indicators with isotonically measured binding affinities in the 39-112 mM range. KRaIONs functioned in HeLa cells, but the values differed from the isotonically measured case. We found that, by tuning the experimental conditions, values could be obtained that were consistent and . We thus recommend characterizing potassium indicator in the physiological context of interest before application.
PubMed: 35427452
DOI: 10.1021/acssensors.1c02201
主引用文献が同じPDBエントリー
実験手法
SOLUTION NMR
構造検証レポート
Validation report summary of 7pvc
検証レポート(詳細版)ダウンロードをダウンロード

248335

件を2026-01-28に公開中

PDB statisticsPDBj update infoContact PDBjnumon