6Q88
RT structure of HEWL at 5 kGy
6Q88 の概要
| エントリーDOI | 10.2210/pdb6q88/pdb |
| 分子名称 | Lysozyme C, DI(HYDROXYETHYL)ETHER, CHLORIDE ION, ... (4 entities in total) |
| 機能のキーワード | antimicrobial, hydrolase, low-dose, serial crystallography |
| 由来する生物種 | Gallus gallus (Chicken) |
| タンパク質・核酸の鎖数 | 1 |
| 化学式量合計 | 14472.73 |
| 構造登録者 | de la Mora, E.,Coquelle, N.,Bury, C.S.,Rosenthal, M.,Garman, E.F.,Burghammer, M.,Colletier, J.P.,Weik, M. (登録日: 2018-12-14, 公開日: 2020-01-15, 最終更新日: 2024-11-20) |
| 主引用文献 | de la Mora, E.,Coquelle, N.,Bury, C.S.,Rosenthal, M.,Holton, J.M.,Carmichael, I.,Garman, E.F.,Burghammer, M.,Colletier, J.P.,Weik, M. Radiation damage and dose limits in serial synchrotron crystallography at cryo- and room temperatures. Proc.Natl.Acad.Sci.USA, 117:4142-4151, 2020 Cited by PubMed Abstract: Radiation damage limits the accuracy of macromolecular structures in X-ray crystallography. Cryogenic (cryo-) cooling reduces the global radiation damage rate and, therefore, became the method of choice over the past decades. The recent advent of serial crystallography, which spreads the absorbed energy over many crystals, thereby reducing damage, has rendered room temperature (RT) data collection more practical and also extendable to microcrystals, both enabling and requiring the study of specific and global radiation damage at RT. Here, we performed sequential serial raster-scanning crystallography using a microfocused synchrotron beam that allowed for the collection of two series of 40 and 90 full datasets at 2- and 1.9-Å resolution at a dose rate of 40.3 MGy/s on hen egg white lysozyme (HEWL) crystals at RT and cryotemperature, respectively. The diffraction intensity halved its initial value at average doses () of 0.57 and 15.3 MGy at RT and 100 K, respectively. Specific radiation damage at RT was observed at disulfide bonds but not at acidic residues, increasing and then apparently reversing, a peculiar behavior that can be modeled by accounting for differential diffraction intensity decay due to the nonuniform illumination by the X-ray beam. Specific damage to disulfide bonds is evident early on at RT and proceeds at a fivefold higher rate than global damage. The decay modeling suggests it is advisable not to exceed a dose of 0.38 MGy per dataset in static and time-resolved synchrotron crystallography experiments at RT. This rough yardstick might change for proteins other than HEWL and at resolutions other than 2 Å. PubMed: 32047034DOI: 10.1073/pnas.1821522117 主引用文献が同じPDBエントリー |
| 実験手法 | X-RAY DIFFRACTION (1.74007062403 Å) |
構造検証レポート
検証レポート(詳細版)
をダウンロード