Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6MV0

CO-bound Sperm Whale Myoglobin, room temperature structure solved by serial 5degree oscillation crystallography

Summary for 6MV0
Entry DOI10.2210/pdb6mv0/pdb
Related6MUH 6MUY 6MUZ
DescriptorMyoglobin, PROTOPORPHYRIN IX CONTAINING FE, CARBON MONOXIDE, ... (5 entities in total)
Functional Keywordsoxygen transporter, myoglobin, transport protein
Biological sourcePhyseter catodon (Sperm whale)
Total number of polymer chains1
Total formula weight18106.71
Authors
Finke, A.D.,Wierman, J.L.,Pare-Labrosse, O.,Sarrachini, A.,Besaw, J.,Mehrabi, P.,Gruner, S.M.,Miller, R.J.D. (deposition date: 2018-10-24, release date: 2019-03-27, Last modification date: 2023-10-11)
Primary citationWierman, J.L.,Pare-Labrosse, O.,Sarracini, A.,Besaw, J.E.,Cook, M.J.,Oghbaey, S.,Daoud, H.,Mehrabi, P.,Kriksunov, I.,Kuo, A.,Schuller, D.J.,Smith, S.,Ernst, O.P.,Szebenyi, D.M.E.,Gruner, S.M.,Miller, R.J.D.,Finke, A.D.
Fixed-target serial oscillation crystallography at room temperature.
IUCrJ, 6:305-316, 2019
Cited by
PubMed Abstract: A fixed-target approach to high-throughput room-temperature serial synchrotron crystallography with oscillation is described. Patterned silicon chips with microwells provide high crystal-loading density with an extremely high hit rate. The microfocus, undulator-fed beamline at CHESS, which has compound refractive optics and a fast-framing detector, was built and optimized for this experiment. The high-throughput oscillation method described here collects 1-5° of data per crystal at room temperature with fast (10° s) oscillation rates and translation times, giving a crystal-data collection rate of 2.5 Hz. Partial datasets collected by the oscillation method at a storage-ring source provide more complete data per crystal than still images, dramatically lowering the total number of crystals needed for a complete dataset suitable for structure solution and refinement - up to two orders of magnitude fewer being required. Thus, this method is particularly well suited to instances where crystal quantities are low. It is demonstrated, through comparison of first and last oscillation images of two systems, that dose and the effects of radiation damage can be minimized through fast rotation and low angular sweeps for each crystal.
PubMed: 30867928
DOI: 10.1107/S2052252519001453
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (1.97 Å)
Structure validation

231029

数据于2025-02-05公开中

PDB statisticsPDBj update infoContact PDBjnumon