Loading
PDBj
メニューPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6M52

Human apo ferritin frozen on TEM grid with amorphous carbon supporting film

6M52 の概要
エントリーDOI10.2210/pdb6m52/pdb
関連するPDBエントリー2FHA
EMDBエントリー30083
分子名称Ferritin heavy chain, FE (II) ION (3 entities in total)
機能のキーワードapoferritin heavy chain, homo sapiens, metal transport, oxidoreductase
由来する生物種Homo sapiens (Human)
タンパク質・核酸の鎖数24
化学式量合計510470.81
構造登録者
Huang, X.,Zhang, L.,Wen, Z.,Chen, H.,Li, S.,Ji, G.,Yin, C.,Sun, F. (登録日: 2020-03-09, 公開日: 2020-05-13, 最終更新日: 2024-03-27)
主引用文献Huang, X.,Zhang, L.,Wen, Z.,Chen, H.,Li, S.,Ji, G.,Yin, C.C.,Sun, F.
Amorphous nickel titanium alloy film: A new choice for cryo electron microscopy sample preparation.
Prog.Biophys.Mol.Biol., 156:3-13, 2020
Cited by
PubMed Abstract: Cryo-electron microscopy (cryoEM) has become one of the most important approach for structural biology. However, barriers are still there for an increased successful rate, a better resolution and improved efficiency from sample preparation, data collection to image processing. CryoEM sample preparation is one of the bottlenecks with many efforts made recently, including the optimization of supporting substrate (e.g. ultra-thin carbon, graphene, pure gold, 2d crystal of streptavidin, and affinity modification), which was aimed to solve air-water interface problem, or reduce beam induced motion (BIM), or change particle distribution in the grid hole. Here, we report another effort of developing a new supporting substrate, the amorphous nickel-titanium alloy (ANTA) film, for cryoEM sample preparation as a layer of holey supporting film covering on TEM grid. Our investigations showed advantages of ANTA film in comparison with conventional carbon film, including much better electron conductivity and trace non-specific interaction with protein. These advantages yield less BIM and significantly improved particle distribution during cryoEM experiment of human apo-ferritn, thus resulting an improved reconstruction resolution from a reduced number of micrographs and particles. Unlike the pure gold film, the usage of the ANTA film is just same with the carbon film, compatible to conventional automatic cryoEM data collection procedure.
PubMed: 32758492
DOI: 10.1016/j.pbiomolbio.2020.07.009
主引用文献が同じPDBエントリー
実験手法
ELECTRON MICROSCOPY (2.6 Å)
構造検証レポート
Validation report summary of 6m52
検証レポート(詳細版)ダウンロードをダウンロード

246905

件を2025-12-31に公開中

PDB statisticsPDBj update infoContact PDBjnumon