6HAL
Human carbonmonoxy hemoglobin SFX dataset
6HAL の概要
| エントリーDOI | 10.2210/pdb6hal/pdb |
| 分子名称 | Hemoglobin subunit alpha, Hemoglobin subunit beta, PROTOPORPHYRIN IX CONTAINING FE, ... (5 entities in total) |
| 機能のキーワード | human carbonmonoxy hemoglobin, r-state, sfx, oxygen transport |
| 由来する生物種 | Homo sapiens (Human) 詳細 |
| タンパク質・核酸の鎖数 | 4 |
| 化学式量合計 | 63948.18 |
| 構造登録者 | Doak, B.,Gorel, A.,Foucar, L.,Barends, T.R.M.,Gruenbein, M.L.,Hilpert, M.,Kloos, M.,Nass Kovacs, G.,Roome, C.M.,Shoeman, R.L.,Stricker, M.,Tono, K.,You, D.,Ueda, K.,Sherrell, D.A.,Owen, R.L.,Schlichting, I. (登録日: 2018-08-07, 公開日: 2018-10-17, 最終更新日: 2024-01-17) |
| 主引用文献 | Doak, R.B.,Nass Kovacs, G.,Gorel, A.,Foucar, L.,Barends, T.R.M.,Grunbein, M.L.,Hilpert, M.,Kloos, M.,Roome, C.M.,Shoeman, R.L.,Stricker, M.,Tono, K.,You, D.,Ueda, K.,Sherrell, D.A.,Owen, R.L.,Schlichting, I. Crystallography on a chip - without the chip: sheet-on-sheet sandwich. Acta Crystallogr D Struct Biol, 74:1000-1007, 2018 Cited by PubMed Abstract: Crystallography chips are fixed-target supports consisting of a film (for example Kapton) or wafer (for example silicon) that is processed using semiconductor-microfabrication techniques to yield an array of wells or through-holes in which single microcrystals can be lodged for raster-scan probing. Although relatively expensive to fabricate, chips offer an efficient means of high-throughput sample presentation for serial diffraction data collection at synchrotron or X-ray free-electron laser (XFEL) sources. Truly efficient loading of a chip (one microcrystal per well and no wastage during loading) is nonetheless challenging. The wells or holes must match the microcrystal size of interest, requiring that a large stock of chips be maintained. Raster scanning requires special mechanical drives to step the chip rapidly and with micrometre precision from well to well. Here, a `chip-less' adaptation is described that essentially eliminates the challenges of loading and precision scanning, albeit with increased, yet still relatively frugal, sample usage. The device consists simply of two sheets of Mylar with the crystal solution sandwiched between them. This sheet-on-sheet (SOS) sandwich structure has been employed for serial femtosecond crystallography data collection with micrometre-sized crystals at an XFEL. The approach is also well suited to time-resolved pump-probe experiments, in particular for long time delays. The SOS sandwich enables measurements under XFEL beam conditions that would damage conventional chips, as documented here. The SOS sheets hermetically seal the sample, avoiding desiccation of the sample provided that the X-ray beam does not puncture the sheets. This is the case with a synchrotron beam but not with an XFEL beam. In the latter case, desiccation, setting radially outwards from each punched hole, sets lower limits on the speed and line spacing of the raster scan. It is shown that these constraints are easily accommodated. PubMed: 30289410DOI: 10.1107/S2059798318011634 主引用文献が同じPDBエントリー |
| 実験手法 | X-RAY DIFFRACTION (2.2 Å) |
構造検証レポート
検証レポート(詳細版)
をダウンロード






