Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6H2M

Long wavelength Mesh&Collect native SAD phasing on microcrystals

Summary for 6H2M
Entry DOI10.2210/pdb6h2m/pdb
DescriptorConcanavalin-A,Concanavalin-A, MANGANESE (II) ION, CALCIUM ION, ... (4 entities in total)
Functional Keywordsconcanavalin a, lectin, long wavelength, mesh&collect, softer x-rays, sugar binding protein
Biological sourceCanavalia ensiformis (Jack bean)
More
Total number of polymer chains1
Total formula weight25717.40
Authors
Cianci, M.,Nanao, M.,Schneider, T.R. (deposition date: 2018-07-13, release date: 2019-03-13, Last modification date: 2024-05-15)
Primary citationCianci, M.,Nanao, M.,Schneider, T.R.
Long-wavelength Mesh&Collect native SAD phasing from microcrystals.
Acta Crystallogr D Struct Biol, 75:192-199, 2019
Cited by
PubMed Abstract: Harnessing the anomalous signal from macromolecular crystals with volumes of less than 10 000 µm for native phasing requires careful experimental planning. The type of anomalous scatterers that are naturally present in the sample, such as sulfur, phosphorus and calcium, will dictate the beam energy required and determine the level of radiation sensitivity, while the crystal size will dictate the beam size and the sample-mounting technique, in turn indicating the specifications of a suitable beamline. On the EMBL beamline P13 at PETRA III, Mesh&Collect data collection from concanavalin A microcrystals with linear dimensions of ∼20 µm or less using an accordingly sized microbeam at a wavelength of 1.892 Å (6.551 keV, close to the Mn edge at 6.549 keV) increases the expected Bijvoet ratio to 2.1% from an expected 0.7% at 12.6 keV (Se K edge), thus allowing experimental phase determination using the anomalous signal from naturally present Mn and Ca ions. Dozens of crystals were harvested and flash-cryocooled in micro-meshes, rapidly screened for diffraction (less than a minute per loop) and then used for serial Mesh&Collect collection of about 298 partial data sets (10° of crystal rotation per sample). The partial data sets were integrated and scaled. A genetic algorithm for combining partial data sets was used to select those to be merged into a single data set. This final data set showed high completeness, high multiplicity and sufficient anomalous signal to locate the anomalous scatterers, and provided phasing information which allowed complete auto-tracing of the polypeptide chain. To allow the complete experiment to run in less than 2 h, a practically acceptable time frame, the diffractometer and detector had to run together with limited manual intervention. The combination of several cutting-edge components allowed accurate anomalous signal to be measured from small crystals.
PubMed: 30821707
DOI: 10.1107/S2059798319002031
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (1.929 Å)
Structure validation

237423

数据于2025-06-11公开中

PDB statisticsPDBj update infoContact PDBjnumon