Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5GX5

Luciferin-regenerating enzyme collected with serial synchrotron rotational crystallography with accumulated dose of 26 MGy (23rd measurement)

Summary for 5GX5
Entry DOI10.2210/pdb5gx5/pdb
Related5GX1 5GX2 5GX3 5GX4
DescriptorLuciferin regenerating enzyme, MERCURY (II) ION, MAGNESIUM ION, ... (6 entities in total)
Functional Keywordsbeta-prooeller, hydrolase
Biological sourcePhotinus pyralis (Common eastern firefly)
Total number of polymer chains1
Total formula weight34755.04
Authors
Hasegawa, K.,Yamashita, K.,Murai, T.,Nuemket, N.,Hirata, K.,Ueno, G.,Ago, H.,Nakatsu, T.,Kumasaka, T.,Yamamoto, M. (deposition date: 2016-09-15, release date: 2017-01-04, Last modification date: 2023-11-08)
Primary citationHasegawa, K.,Yamashita, K.,Murai, T.,Nuemket, N.,Hirata, K.,Ueno, G.,Ago, H.,Nakatsu, T.,Kumasaka, T.,Yamamoto, M.
Development of a dose-limiting data collection strategy for serial synchrotron rotation crystallography
J Synchrotron Radiat, 24:29-41, 2017
Cited by
PubMed Abstract: Serial crystallography, in which single-shot diffraction images are collected, has great potential for protein microcrystallography. Although serial femtosecond crystallography (SFX) has been successfully demonstrated, limited beam time prevents its routine use. Inspired by SFX, serial synchrotron crystallography (SSX) has been investigated at synchrotron macromolecular crystallography beamlines. Unlike SFX, the longer exposure time of milliseconds to seconds commonly used in SSX causes radiation damage. However, in SSX, crystals can be rotated during the exposure, which can achieve efficient coverage of the reciprocal space. In this study, mercury single-wavelength anomalous diffraction (Hg-SAD) phasing of the luciferin regenerating enzyme (LRE) was performed using serial synchrotron rotation crystallography. The advantages of rotation and influence of dose on the data collected were evaluated. The results showed that sample rotation was effective for accurate data collection, and the optimum helical rotation step depended on multiple factors such as multiplicity and partiality of reflections, exposure time per rotation angle and the contribution from background scattering. For the LRE microcrystals, 0.25° was the best rotation step for the achievable resolution limit, whereas a rotation step larger than or equal to 1° was favorable for Hg-SAD phasing. Although an accumulated dose beyond 1.1 MGy caused specific damage at the Hg site, increases in resolution and anomalous signal were observed up to 3.4 MGy because of a higher signal-to-noise ratio.
PubMed: 28009544
DOI: 10.1107/S1600577516016362
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (1.6 Å)
Structure validation

226707

數據於2024-10-30公開中

PDB statisticsPDBj update infoContact PDBjnumon