Loading
PDBj
メニューPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5GX4

Luciferin-regenerating enzyme collected with serial synchrotron rotational crystallography with accumulated dose of 14 MGy (12th measurement)

5GX4 の概要
エントリーDOI10.2210/pdb5gx4/pdb
関連するPDBエントリー5GX1 5GX2 5GX3 5GX5
分子名称Luciferin regenerating enzyme, MERCURY (II) ION, MAGNESIUM ION, ... (6 entities in total)
機能のキーワードbeta-prooeller, hydrolase
由来する生物種Photinus pyralis (Common eastern firefly)
タンパク質・核酸の鎖数1
化学式量合計34955.63
構造登録者
Hasegawa, K.,Yamashita, K.,Murai, T.,Nuemket, N.,Hirata, K.,Ueno, G.,Ago, H.,Nakatsu, T.,Kumasaka, T.,Yamamoto, M. (登録日: 2016-09-15, 公開日: 2017-01-04, 最終更新日: 2023-11-08)
主引用文献Hasegawa, K.,Yamashita, K.,Murai, T.,Nuemket, N.,Hirata, K.,Ueno, G.,Ago, H.,Nakatsu, T.,Kumasaka, T.,Yamamoto, M.
Development of a dose-limiting data collection strategy for serial synchrotron rotation crystallography
J Synchrotron Radiat, 24:29-41, 2017
Cited by
PubMed Abstract: Serial crystallography, in which single-shot diffraction images are collected, has great potential for protein microcrystallography. Although serial femtosecond crystallography (SFX) has been successfully demonstrated, limited beam time prevents its routine use. Inspired by SFX, serial synchrotron crystallography (SSX) has been investigated at synchrotron macromolecular crystallography beamlines. Unlike SFX, the longer exposure time of milliseconds to seconds commonly used in SSX causes radiation damage. However, in SSX, crystals can be rotated during the exposure, which can achieve efficient coverage of the reciprocal space. In this study, mercury single-wavelength anomalous diffraction (Hg-SAD) phasing of the luciferin regenerating enzyme (LRE) was performed using serial synchrotron rotation crystallography. The advantages of rotation and influence of dose on the data collected were evaluated. The results showed that sample rotation was effective for accurate data collection, and the optimum helical rotation step depended on multiple factors such as multiplicity and partiality of reflections, exposure time per rotation angle and the contribution from background scattering. For the LRE microcrystals, 0.25° was the best rotation step for the achievable resolution limit, whereas a rotation step larger than or equal to 1° was favorable for Hg-SAD phasing. Although an accumulated dose beyond 1.1 MGy caused specific damage at the Hg site, increases in resolution and anomalous signal were observed up to 3.4 MGy because of a higher signal-to-noise ratio.
PubMed: 28009544
DOI: 10.1107/S1600577516016362
主引用文献が同じPDBエントリー
実験手法
X-RAY DIFFRACTION (1.6 Å)
構造検証レポート
Validation report summary of 5gx4
検証レポート(詳細版)ダウンロードをダウンロード

234136

件を2025-04-02に公開中

PDB statisticsPDBj update infoContact PDBjnumon