4V2D
FLRT2 LRR domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | MARRESEARCH |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.120, 41.450, 87.350 |
Unit cell angles | 90.00, 102.91, 90.00 |
Refinement procedure
Resolution | 42.570 - 2.500 |
R-factor | 0.2808 |
Rwork | 0.280 |
R-free | 0.30100 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.960 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.000 | 2.560 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.120 | |
Number of reflections | 26383 | |
<I/σ(I)> | 6.6 | 0.51 |
Completeness [%] | 78.8 | 33 |
Redundancy | 2.9 | 1.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |