102M
SPERM WHALE MYOGLOBIN H64A AQUOMET AT PH 9.0
Experimental procedure
Source type | ROTATING ANODE |
Source details | SIEMENS |
Temperature [K] | 292 |
Detector technology | IMAGE PLATE |
Collection date | 1996-10 |
Detector | RIGAKU |
Spacegroup name | P 6 |
Unit cell lengths | 91.433, 91.433, 45.949 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 5.000 - 1.840 |
R-factor | 0.159 |
Rwork | 0.159 |
R-free | 0.20300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | SPERM WHALE MYOGLOBIN 0M D122N (DEOXY) |
RMSD bond length | 0.009 |
RMSD bond angle | 1.400 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | X-PLOR (3.851) |
Refinement software | X-PLOR (3.851) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 6.000 | 1.850 |
High resolution limit [Å] | 1.840 | 1.840 |
Rmerge | 0.062 | 0.267 |
Number of reflections | 17484 | |
Completeness [%] | 90.9 | 98.4 |
Redundancy | 5.63 | 4.35 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 9 | 3.0 M AMMONIUM SULFATE, 20 MM TRIS, 1MM EDTA, PH 9.0 |