ジャーナル: Proc Natl Acad Sci U S A / 年: 2009 タイトル: Survey of large protein complexes in D. vulgaris reveals great structural diversity. 著者: Bong-Gyoon Han / Ming Dong / Haichuan Liu / Lauren Camp / Jil Geller / Mary Singer / Terry C Hazen / Megan Choi / H Ewa Witkowska / David A Ball / Dieter Typke / Kenneth H Downing / Maxim ...著者: Bong-Gyoon Han / Ming Dong / Haichuan Liu / Lauren Camp / Jil Geller / Mary Singer / Terry C Hazen / Megan Choi / H Ewa Witkowska / David A Ball / Dieter Typke / Kenneth H Downing / Maxim Shatsky / Steven E Brenner / John-Marc Chandonia / Mark D Biggin / Robert M Glaeser / 要旨: An unbiased survey has been made of the stable, most abundant multi-protein complexes in Desulfovibrio vulgaris Hildenborough (DvH) that are larger than Mr approximately 400 k. The quaternary ...An unbiased survey has been made of the stable, most abundant multi-protein complexes in Desulfovibrio vulgaris Hildenborough (DvH) that are larger than Mr approximately 400 k. The quaternary structures for 8 of the 16 complexes purified during this work were determined by single-particle reconstruction of negatively stained specimens, a success rate approximately 10 times greater than that of previous "proteomic" screens. In addition, the subunit compositions and stoichiometries of the remaining complexes were determined by biochemical methods. Our data show that the structures of only two of these large complexes, out of the 13 in this set that have recognizable functions, can be modeled with confidence based on the structures of known homologs. These results indicate that there is significantly greater variability in the way that homologous prokaryotic macromolecular complexes are assembled than has generally been appreciated. As a consequence, we suggest that relying solely on previously determined quaternary structures for homologous proteins may not be sufficient to properly understand their role in another cell of interest.
Legacy - 非点収差: objective lens astigmatism was corrected at 60,000 times magnification
日付
2008年7月8日
撮影
カテゴリ: FILM / フィルム・検出器のモデル: KODAK SO-163 FILM デジタル化 - スキャナー: NIKON SUPER COOLSCAN 9000 デジタル化 - サンプリング間隔: 6.35 µm / 実像数: 85 / 平均電子線量: 17 e/Å2 詳細: The images were scanned with a resolution of 6.35 micro m per pixel and later averaged 2 fold in each direction. ビット/ピクセル: 8
Tilt angle min
0
Tilt angle max
0
-
画像解析
CTF補正
詳細: Each particle
最終 再構成
アルゴリズム: OTHER / 解像度のタイプ: BY AUTHOR / 解像度: 24.0 Å / 解像度の算出法: FSC 0.5 CUT-OFF / ソフトウェア - 名称: SPIDER / 使用した粒子像数: 11000