Specimen Holder | ~ 2 A | ~ 3 A | ~ 5 A | ~ 7 A | ~ 10 A | ~ 15 A | ~ 23 A | ~ 34 A | ~ 51 A | ~ 77 A | ~ 115 A | ~ 173 A | Total |
---|
CARTRIDGE | | | | | | 7 | | | | | | | 7 |
CRYO | | | | | | 2 | | | | | | | 2 |
CRYO, LIQ-N2, SINGLE TILT | | | | | 1 | | | | | | | | 1 |
CRYO, SINGLE TILT | | | | | | | | | | | | | 1 |
EUCENTRIC | | | 6 | | 3 | 11 | 8 | 2 | | | | | 30 |
FEI POLARA CARTRIDGE | | | 3 | | | | | | | | | | 3 |
FEI POLARA CARTRIDGE ... | | | | 1 | | | | | | | | | 1 |
FEI POLARA LOADER | | | 1 | | | | | | | | | | 1 |
FEI TITAN KRIOS AUTOGRID | 140 | 2504 | 7488 | 896 | 934 | 380 | 452 | 431 | 100 | 9 | 8 | 2 | 13722 |
FEI, SINGLE TILT | | | | | | | | 1 | | | | | 1 |
FISCHIONE 2550 | | | 1 | | | | | | | | | | 2 |
FISCHIONE DUAL AXIS T... | | | | | | 3 | 5 | | | | | | 10 |
GATAN | | | | | 1 | | | | | | | | 1 |
GATAN 626 | 27 | 13 | 89 | 36 | 36 | 26 | 45 | 26 | 32 | 6 | 9 | | 371 |
GATAN 910 | | | 14 | 1 | 8 | 7 | 1 | | | | | | 32 |
GATAN 914 | | | | | 2 | | 4 | 2 | 30 | 3 | 10 | 1 | 62 |
GATAN 915 | | | | 1 | | | | | | | | | 1 |
GATAN ELSA 698, LIQ-N... | | 1 | 7 | | 3 | | | 1 | | | | | 12 |
GATAN HCH, SINGLE TIL... | | | 1 | | | | | | | | | | 1 |
GATAN ULT, SINGLE TIL... | | | 7 | | | | | | | | | | 7 |
GATAN, LIQ-HE | | | 9 | 13 | 15 | 13 | 14 | 1 | 6 | 8 | 2 | | 87 |
GATAN, LIQ-N2 | 2 | 3 | 98 | 65 | 309 | 347 | 392 | 235 | 160 | 35 | 5 | | 1777 |
GATAN, SIDE ENTRY | | | 1 | 4 | 2 | 1 | | | | | | | 8 |
HOME BUILD | | | | | | 1 | 7 | 3 | | | | | 11 |
JEOL | 2 | 9 | 14 | 5 | 23 | 13 | 53 | 53 | 9 | | | | 183 |
JEOL 3200FSC CRYO | 1 | | 27 | 12 | 24 | 11 | 3 | 3 | 3 | 2 | | | 99 |
JEOL CRYOSPECPORTER | 11 | 58 | 77 | 13 | 5 | | | | | | | | 166 |
LIQ-N2 | | 1 | 7 | 1 | 3 | | | | | | | | 12 |
LIQUID N2 COOLED | | | 1 | | | | | | | | | | 1 |
n/a | 475 | 13222 | 33538 | 2511 | 2095 | 967 | 1113 | 959 | 303 | 75 | 38 | 4 | 56398 |
OTHER | | 20 | 169 | 35 | 115 | 82 | 156 | 147 | 55 | 23 | 1 | | 871 |
OXD | | | | | 1 | | | | | | | | 1 |
OXD CT3500 | | | 2 | | 1 | 6 | | 6 | 6 | 38 | 66 | 11 | 138 |
OXD, CRYO, SIDE ENTRY | | | | 1 | | 1 | | | | | | | 2 |
PHILIPS ROTATION | | | 1 | 1 | 3 | 1 | 19 | 6 | 1 | | | | 34 |
POLARA | | | 4 | | | | | | | | | | 4 |
POLARA CARTRIDGE | | | | | 2 | 1 | | | | | | | 3 |
POLARA CARTRIDGE-LOAD... | | | 1 | | | | | | | | | | 1 |
POLARA MULTI | | | | | 1 | | | | | | | | 1 |
POLRAR MULTI | | | | | 1 | | | | | | | | 1 |
ROOM TEMP | | | | | | | | 1 | | | | | 1 |
SIDE ENTRY | | | 4 | 1 | 4 | | | | 1 | | | | 10 |
SIDE ENTRY, EUCENTRIC | | 1 | 11 | 5 | 18 | 44 | 446 | 380 | 48 | 56 | 4 | | 1035 |
SIDE ENTRY, LIQ-N2 | | | | 3 | 4 | 7 | 8 | | | | | | 22 |
SINGLE TILT | | | | | | 2 | | | 2 | | | | 4 |
STANDARD, SIDE ENTRY,... | | | | | | | 1 | | | | | | 1 |
TITAN KRIOS | | | 2 | | | | | | | | | | 2 |
TITAN KRIOS CRYO | | | | | 1 | | | | | | | | 1 |
TOMOGRAPHY, SIDE ENTR... | | | | | | | | 1 | | | | | 1 |
TOP ENTRY, LIQ-HE | | | | | 1 | 1 | | | | | | | 2 |
UNIDENTIFIED | | | | | | | | | | | | | 2 |
UNSPECIFIED | | | 1 | | 5 | | | | | | | | 6 |