-Display options
Row key | Entry: Submission Year Authors Processing Site Article: Journal Name Country Sample: Component Species Aggregation State Molecular Weight (MDa) Experiment: Cryogen Name Instrument for Vitrification Specimen Holder Specimen Temperature Microscope Accelerating Voltage Electron Source Detector Processing: Method Resolution Resolution Method CTF correction 3D reconstruction Algorithm Software fo 3D reconstruction Software for modeling |
---|---|
Column key | None (bar graph) Submission Year Method Resolution |
Database | Sum of both (57143) EMDB (36223) PDB (20920) |
-Annotation about this statistics
- Some data are modified
- Detector: [modified] Tietz/TVIPS => TIETZ, [modified] Pixel number (e.g. 4K x 4K) => removed
- Counted not per "structre" but per data entry
- Click column head to sort ([Shift] + click for multi-column sort)
-Statistics - Detector vs. Resolution
Detector | ~ 2 A | ~ 3 A | ~ 5 A | ~ 7 A | ~ 10 A | ~ 15 A | ~ 23 A | ~ 34 A | ~ 51 A | ~ 77 A | ~ 115 A | ~ 173 A | Total |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AGFA SCIEN | 1 | 2 | 3 | ||||||||||
DECTRIS SIN X 1K | 4 | 7 | 11 | ||||||||||
DIRECT ELECTRON APO X 4K | 2 | 2 | 4 | ||||||||||
DIRECT ELECTRON DE X 3K | 5 | 29 | 7 | 6 | 1 | 48 | |||||||
DIRECT ELECTRON DE X 4K | 25 | 6 | 1 | 32 | |||||||||
DIRECT ELECTRON DE X 8K | 2 | 7 | 18 | 1 | 28 | ||||||||
FEI C X 4K | 16 | 21 | 5 | 2 | 1 | 2 | 47 | ||||||
FEI EA X 2K | 1 | 4 | 5 | ||||||||||
FEI EA X 4K | 2 | 1 | 6 | 4 | 6 | 16 | 8 | 4 | 47 | ||||
FEI FALCO X 4K | 1 | 5 | 8 | 5 | 2 | 1 | 22 | ||||||
FEI FALCON X 4K | 54 | 796 | 2201 | 195 | 110 | 36 | 11 | 3 | 3408 | ||||
GATAN GENERIC | 1 | 2 | 1 | 6 | 2 | 3 | 4 | 2 | 21 | ||||
GATAN K2 B X 4K | 17 | 75 | 16 | 8 | 1 | 1 | 118 | ||||||
GATAN K2 QUAN X 4K | 5 | 160 | 691 | 34 | 78 | 13 | 7 | 1 | 4 | 994 | |||
GATAN K2 SUM X 4K | 9 | 874 | 4432 | 349 | 249 | 72 | 19 | 9 | 6 | 6033 | |||
GATAN K2 X 4K | 1 | 8 | 9 | 18 | |||||||||
GATAN K3 BIOCONTIN X 4K | 2 | 2 | 4 | ||||||||||
GATAN K3 BIOQUAN X 4K | 38 | 1117 | 2253 | 93 | 52 | 4 | 9 | 3 | 3573 | ||||
GATAN MULTISCAN | 2 | 1 | 4 | 2 | 3 | 12 | |||||||
GATAN ORIUS SC600 2.7... | 1 | 1 | |||||||||||
GATAN ULTRASCAN 1 X 2K | 1 | 3 | 1 | 5 | |||||||||
GATAN ULTRASCAN 10 X 10K | 1 | 1 | 1 | 1 | 4 | ||||||||
GATAN ULTRASCAN 4 X 4K | 8 | 3 | 21 | 18 | 34 | 29 | 21 | 7 | 10 | 155 | |||
GATAN X 4K | 25 | 1607 | 3590 | 130 | 107 | 21 | 3 | 4 | 5490 | ||||
GENER | 8 | 1 | 5 | 4 | 11 | 1 | 30 | ||||||
GENERIC CCD | 2 | 2 | 1 | 3 | 7 | 5 | 2 | 22 | |||||
GENERIC GA X 2K | 1 | 1 | 1 | 1 | 4 | ||||||||
GENERIC GA X 4K | 1 | 1 | 2 | 4 | |||||||||
GENERIC IMAGE PLATES | 1 | 1 | |||||||||||
GENERIC TV X 4K | 1 | 1 | 4 | 9 | 15 | ||||||||
GENERIC X 2K | 1 | 1 | |||||||||||
KODAK 44 | 1 | 1 | |||||||||||
KODAK SO-1 | 2 | 48 | 28 | 137 | 121 | 56 | 19 | 3 | 11 | 428 | |||
n/a | 2 | 7 | 4 | 4 | 13 | 1 | 34 | ||||||
OTHER | 5 | 17 | 40 | 4 | 2 | 1 | 1 | 3 | 73 | ||||
TFS FALCON X 4K | 10 | 24 | 11 | 1 | 2 | 48 | |||||||
TFS FALCON X 4X | 1 | 1 | |||||||||||
TIETZ GENERIC | 1 | 1 | 1 | 3 | |||||||||
TIETZ TEMCAM F X 2K | 2 | 1 | 2 | 8 | 2 | 15 | |||||||
TIETZ TEMCAM F X 4K | 69 | 14 | 9 | 7 | 23 | 9 | 4 | 2 | 139 | ||||
TIETZ TEMCAM F X 8K | 2 | 14 | 1 | 1 | 18 |
Download: CSV format (Comma-Separated Values, for Excel, etc.) / TSV format (Tab Separated Values)