Display options
| Row key | Entry: Submission Year Authors Processing Site Article: Journal Name Country Sample: Component Species Aggregation State Molecular Weight (MDa) Experiment: Cryogen Name Instrument for Vitrification Specimen Holder Specimen Temperature Microscope Accelerating Voltage Electron Source Detector Processing: Method Resolution Resolution Method CTF correction 3D reconstruction Algorithm Software fo 3D reconstruction Software for modeling |
|---|---|
| Column key | None (bar graph) Submission Year Method Resolution |
| Database | Sum of both (93344) EMDB (58426) PDB (34918) |
-Annotation about this statistics
- Some data are modified
- Detector: [modified] Tietz/TVIPS => TIETZ, [modified] Pixel number (e.g. 4K x 4K) => removed
- Counted not per "structre" but per data entry
- Click column head to sort ([Shift] + click for multi-column sort)
-Statistics - Detector vs. Method
| Detector | electron crystallography | helical | single particle | subtomogram averaging | electron tomography | Total |
|---|---|---|---|---|---|---|
| AGFA SCIEN | 3 | 9 | 12 | |||
| DECTRIS ARINA 0.2K X 0.2K | 1 | 4 | 5 | |||
| DECTRIS SIN X 1K | 12 | 12 | ||||
| DECTRIS X 0.5K | 2 | 4 | 6 | |||
| DIRECT ELECTRON APO X 4K | 1 | 33 | 34 | |||
| DIRECT ELECTRON DE X 3K | 3 | 136 | 20 | 21 | 180 | |
| DIRECT ELECTRON DE X 4K | 4 | 51 | 3 | 7 | 65 | |
| DIRECT ELECTRON DE X 8K | 48 | 2 | 50 | |||
| FEI C X 4K | 49 | 14 | 280 | 1 | 344 | |
| FEI EA X 2K | 57 | 2 | 1 | 60 | ||
| FEI EA X 4K | 2 | 9 | 479 | 6 | 14 | 510 |
| FEI FALCO X 4K | 2 | 83 | 9 | 2 | 96 | |
| FEI FALCON X 4K | 21 | 672 | 8851 | 374 | 280 | 10198 |
| GATAN ALPINE 2.3K X 3.2K | 5 | 5 | ||||
| GATAN GENERIC | 1 | 2 | 24 | 18 | 8 | 53 |
| GATAN K2 B X 4K | 1 | 3 | 194 | 6 | 12 | 216 |
| GATAN K2 QUAN X 4K | 1 | 63 | 1541 | 279 | 325 | 2209 |
| GATAN K2 SUM X 4K | 1 | 459 | 9083 | 907 | 495 | 10945 |
| GATAN K2 X 4K | 5 | 36 | 41 | |||
| GATAN K3 BIOCONTIN X 4K | 74 | 508 | 20 | 70 | 672 | |
| GATAN K3 BIOQUAN X 4K | 408 | 9925 | 484 | 738 | 11555 | |
| GATAN MULTISCAN | 10 | 33 | 12 | 55 | ||
| GATAN ORIUS SC X 2K | 7 | 1 | 4 | 12 | ||
| GATAN ORIUS SC1 X 2.7K | 2 | 5 | 7 | |||
| GATAN ORIUS SC600 2.7... | 2 | 2 | ||||
| GATAN ULTRASCAN 1 X 2K | 2 | 33 | 65 | 17 | 117 | |
| GATAN ULTRASCAN 10 X 10K | 6 | 6 | ||||
| GATAN ULTRASCAN 4 X 4K | 11 | 49 | 601 | 86 | 509 | 1256 |
| GATAN X 4K | 2 | 555 | 13787 | 443 | 206 | 14993 |
| GENER | 2 | 9 | 11 | |||
| GENERIC CCD | 1 | 62 | 47 | 3 | 113 | |
| GENERIC GA X 2K | 4 | 6 | 7 | 17 | ||
| GENERIC GA X 4K | 1 | 3 | 103 | 1 | 3 | 111 |
| GENERIC IMAGE PLATES | 3 | 3 | ||||
| GENERIC TV X 2K | 3 | 3 | ||||
| GENERIC TV X 4K | 71 | 6 | 77 | |||
| GENERIC X 2K | 5 | 6 | 11 | |||
| KODAK 44 | 13 | 13 | ||||
| KODAK SO-1 | 31 | 117 | 928 | 1076 | ||
| n/a | 3 | 15 | 203 | 49 | 7 | 277 |
| OTHER | 2 | 6 | 346 | 7 | 63 | 424 |
| PROSCAN TEM- X 2K | 1 | 1 | ||||
| SIA X 3K | 4 | 4 | ||||
| TFS FALCON X 4K | 1 | 43 | 1133 | 142 | 17 | 1336 |
| TIETZ GENERIC | 3 | 8 | 11 | |||
| TIETZ TEMCAM F X 2K | 2 | 19 | 15 | 21 | 57 | |
| TIETZ TEMCAM F X 4K | 65 | 18 | 892 | 101 | 37 | 1113 |
| TIETZ TEMCAM F X 8K | 9 | 41 | 2 | 52 |