[English] 日本語
Yorodumi- EMDB-13602: Tomogram of mouse dorsal root ganglion axon (dataset 1, TS_29). -
+Open data
-Basic information
Entry | Database: EMDB / ID: EMD-13602 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Title | Tomogram of mouse dorsal root ganglion axon (dataset 1, TS_29). | |||||||||
Map data | Tomogram of mouse dorsal root ganglion axon. The volume was binned by 4 and deconvolved for visualization. | |||||||||
Sample |
| |||||||||
Biological species | Mus musculus (house mouse) | |||||||||
Method | electron tomography / cryo EM | |||||||||
Authors | Foster HE / Ventura Santos C / Carter AP | |||||||||
Funding support | United Kingdom, 2 items
| |||||||||
Citation | Journal: J Cell Biol / Year: 2022 Title: A cryo-ET survey of microtubules and intracellular compartments in mammalian axons. Authors: Helen E Foster / Camilla Ventura Santos / Andrew P Carter / Abstract: The neuronal axon is packed with cytoskeletal filaments, membranes, and organelles, many of which move between the cell body and axon tip. Here, we used cryo-electron tomography to survey the ...The neuronal axon is packed with cytoskeletal filaments, membranes, and organelles, many of which move between the cell body and axon tip. Here, we used cryo-electron tomography to survey the internal components of mammalian sensory axons. We determined the polarity of the axonal microtubules (MTs) by combining subtomogram classification and visual inspection, finding MT plus and minus ends are structurally similar. Subtomogram averaging of globular densities in the MT lumen suggests they have a defined structure, which is surprising given they likely contain the disordered protein MAP6. We found the endoplasmic reticulum in axons is tethered to MTs through multiple short linkers. We surveyed membrane-bound cargos and describe unexpected internal features such as granules and broken membranes. In addition, we detected proteinaceous compartments, including numerous virus-like capsid particles. Our observations outline novel features of axonal cargos and MTs, providing a platform for identification of their constituents. #1: Journal: Biorxiv / Year: 2021 Title: A cryo-ET survey of intracellular compartments within mammalian axons Authors: Foster HE / Carter AP | |||||||||
History |
|
-Structure visualization
Movie |
Movie viewer |
---|---|
Supplemental images |
-Downloads & links
-EMDB archive
Map data | emd_13602.map.gz | 1.1 GB | EMDB map data format | |
---|---|---|---|---|
Header (meta data) | emd-13602-v30.xml emd-13602.xml | 11.7 KB 11.7 KB | Display Display | EMDB header |
Images | emd_13602.png | 175.5 KB | ||
Archive directory | http://ftp.pdbj.org/pub/emdb/structures/EMD-13602 ftp://ftp.pdbj.org/pub/emdb/structures/EMD-13602 | HTTPS FTP |
-Validation report
Summary document | emd_13602_validation.pdf.gz | 270.9 KB | Display | EMDB validaton report |
---|---|---|---|---|
Full document | emd_13602_full_validation.pdf.gz | 270.5 KB | Display | |
Data in XML | emd_13602_validation.xml.gz | 4.8 KB | Display | |
Data in CIF | emd_13602_validation.cif.gz | 5.3 KB | Display | |
Arichive directory | https://ftp.pdbj.org/pub/emdb/validation_reports/EMD-13602 ftp://ftp.pdbj.org/pub/emdb/validation_reports/EMD-13602 | HTTPS FTP |
-Related structure data
Related structure data | C: citing same article (ref.) |
---|---|
EM raw data | EMPIAR-10815 (Title: Cryo electron tomograms of mouse DRG axons (dataset 1) Data size: 200.8 Data #1: Tomograms of mouse dorsal root ganglion axons (dataset 1) binned by 4 and deconvolved [reconstructed volumes] Data #2: Corrected, aligned, dose-filtered and order-sorted tilt series for mouse dorsal root ganglion axons (dataset 1) [tilt series]) |
-Links
EMDB pages | EMDB (EBI/PDBe) / EMDataResource |
---|
-Map
File | Download / File: emd_13602.map.gz / Format: CCP4 / Size: 1.2 GB / Type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Annotation | Tomogram of mouse dorsal root ganglion axon. The volume was binned by 4 and deconvolved for visualization. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Projections & slices | Image control
Images are generated by Spider. generated in cubic-lattice coordinate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voxel size | X=Y=Z: 13.76 Å | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Density |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Symmetry | Space group: 1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Details | EMDB XML:
CCP4 map header:
|
-Supplemental data
-Sample components
-Entire : Tomogram of a mouse dorsal root ganglion (DRG) axon from dataset ...
Entire | Name: Tomogram of a mouse dorsal root ganglion (DRG) axon from dataset 1 (TS_29). |
---|---|
Components |
|
-Supramolecule #1: Tomogram of a mouse dorsal root ganglion (DRG) axon from dataset ...
Supramolecule | Name: Tomogram of a mouse dorsal root ganglion (DRG) axon from dataset 1 (TS_29). type: cell / ID: 1 / Parent: 0 / Macromolecule list: #1 Details: Example tomogram of a mouse dorsal root ganglion (DRG) axon from dataset 1. Tomogram was used for survey of microtubules and components in axons. Tomogram contains site at which microtubules ...Details: Example tomogram of a mouse dorsal root ganglion (DRG) axon from dataset 1. Tomogram was used for survey of microtubules and components in axons. Tomogram contains site at which microtubules and endoplasmic reticulum are linked by tethers. |
---|---|
Source (natural) | Organism: Mus musculus (house mouse) / Organ: Neurons / Tissue: Dorsal root ganglion |
-Experimental details
-Structure determination
Method | cryo EM |
---|---|
Processing | electron tomography |
Aggregation state | cell |
-Sample preparation
Buffer | pH: 7.4 |
---|---|
Grid | Model: Quantifoil R3.5/1 / Material: GOLD / Mesh: 200 / Support film - Material: CARBON / Support film - topology: CONTINUOUS |
Vitrification | Cryogen name: ETHANE / Chamber humidity: 100 % / Chamber temperature: 310 K / Instrument: FEI VITROBOT MARK IV / Details: Manual blot for 3 s before plunging. |
Details | Adult DRG neurons from GFP-RFP LC3 mouse were grown for 4 days in vitro before vitrification. Tilt series was collected in a thin region of an axon. |
Sectioning | Other: NO SECTIONING |
Fiducial marker | Manufacturer: BBI Solutions / Diameter: 10 nm |
-Electron microscopy
Microscope | FEI TITAN KRIOS |
---|---|
Specialist optics | Energy filter - Name: GIF Bioquantum / Energy filter - Slit width: 20 eV |
Image recording | Film or detector model: GATAN K2 SUMMIT (4k x 4k) / Detector mode: COUNTING / Digitization - Dimensions - Width: 3710 pixel / Digitization - Dimensions - Height: 3838 pixel / Digitization - Frames/image: 1-10 / Average exposure time: 2.5 sec. / Average electron dose: 1.97 e/Å2 Details: 61 images per tilt series with 120.2 e/A2 total dose. A zero-centered tilt scheme from minus 30 to plus 60 degrees then minus 30 to minus 60 degrees was used for acquisition. |
Electron beam | Acceleration voltage: 300 kV / Electron source: FIELD EMISSION GUN |
Electron optics | C2 aperture diameter: 50.0 µm / Illumination mode: FLOOD BEAM / Imaging mode: BRIGHT FIELD / Cs: 2.7 mm / Nominal defocus max: 5.0 µm / Nominal defocus min: 3.0 µm / Nominal magnification: 53000 |
Sample stage | Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER / Cooling holder cryogen: NITROGEN |
Experimental equipment | Model: Titan Krios / Image courtesy: FEI Company |
-Image processing
Details | Frame alignment and dose-filtering was done with alignframes and newstack (IMOD) operated via subTOM. Tilt series alignment and tomogram reconstruction was performed in IMOD. |
---|---|
Final reconstruction | Algorithm: BACK PROJECTION / Software - Name: IMOD (ver. 4.10.32) / Number images used: 61 |