TitleZernike phase contrast cryo-electron microscopy and tomography for structure determination at nanometer and subnanometer resolutions.
Journal, issue, pagesStructure, Vol. 18, Issue 8, Page 903-912, Year 2010
Publish dateAug 11, 2010
AuthorsKazuyoshi Murata / Xiangan Liu / Radostin Danev / Joanita Jakana / Michael F Schmid / Jonathan King / Kuniaki Nagayama / Wah Chiu /
PubMed AbstractZernike phase contrast cryo-electron microscopy (ZPC-cryoEM) is an emerging technique that is capable of producing higher image contrast than conventional cryoEM. By combining this technique with ...Zernike phase contrast cryo-electron microscopy (ZPC-cryoEM) is an emerging technique that is capable of producing higher image contrast than conventional cryoEM. By combining this technique with advanced image processing methods, we achieved subnanometer resolution for two biological specimens: 2D bacteriorhodopsin crystal and epsilon15 bacteriophage. For an asymmetric reconstruction of epsilon15 bacteriophage, ZPC-cryoEM can reduce the required amount of data by a factor of approximately 3, compared with conventional cryoEM. The reconstruction was carried out to 13 A resolution without the need to correct the contrast transfer function. New structural features at the portal vertex of the epsilon15 bacteriophage are revealed in this reconstruction. Using ZPC cryo-electron tomography (ZPC-cryoET), a similar level of data reduction and higher resolution structures of epsilon15 bacteriophage can be obtained relative to conventional cryoET. These results show quantitatively the benefits of ZPC-cryoEM and ZPC-cryoET for structural determinations of macromolecular machines at nanometer and subnanometer resolutions.
External linksStructure / PubMed:20696391 / PubMed Central
MethodsEM (subtomogram averaging) / EM (single particle)
Resolution9.0 - 38.0 Å
Structure data

EMDB-5203:
Subtomogram average of epsilon15 using Zernike phase contrast microscopy
Method: EM (subtomogram averaging) / Resolution: 32.0 Å

EMDB-5204:
Average of 50 Epsilon15 subtomograms using electron cryo-tomography
Method: EM (subtomogram averaging) / Resolution: 38.0 Å

EMDB-5206:
Epsilon15 icosahedral reconstruction using Zernike phase contrast electron microscopy
Method: EM (single particle) / Resolution: 9.0 Å

EMDB-5207:
Epsilon15 asymmetric reconstruction using Zernike phase contrast electron microscopy
Method: EM (single particle) / Resolution: 13.0 Å

EMDB-5208:
Epsilon15 asymmetric reconstruction using Zernike phase contrast electron microscopy (100 particles)
Method: EM (single particle) / Resolution: 26.0 Å

EMDB-5209:
Epsilon15 asymmetric reconstruction using conventional cryo-EM
Method: EM (single particle) / Resolution: 13.0 Å

+
About Yorodumi Papers

-
News

-
Feb 9, 2022. New format data for meta-information of EMDB entries

New format data for meta-information of EMDB entries

  • Version 3 of the EMDB header file is now the official format.
  • The previous official version 1.9 will be removed from the archive.

Related info.:EMDB header

External links:wwPDB to switch to version 3 of the EMDB data model

-
Aug 12, 2020. Covid-19 info

Covid-19 info

URL: https://pdbjlvh1.pdbj.org/emnavi/covid19.php

New page: Covid-19 featured information page in EM Navigator.

Related info.:Covid-19 info / Mar 5, 2020. Novel coronavirus structure data

+
Mar 5, 2020. Novel coronavirus structure data

Novel coronavirus structure data

Related info.:Yorodumi Speices / Aug 12, 2020. Covid-19 info

External links:COVID-19 featured content - PDBj / Molecule of the Month (242):Coronavirus Proteases

+
Jan 31, 2019. EMDB accession codes are about to change! (news from PDBe EMDB page)

EMDB accession codes are about to change! (news from PDBe EMDB page)

  • The allocation of 4 digits for EMDB accession codes will soon come to an end. Whilst these codes will remain in use, new EMDB accession codes will include an additional digit and will expand incrementally as the available range of codes is exhausted. The current 4-digit format prefixed with “EMD-” (i.e. EMD-XXXX) will advance to a 5-digit format (i.e. EMD-XXXXX), and so on. It is currently estimated that the 4-digit codes will be depleted around Spring 2019, at which point the 5-digit format will come into force.
  • The EM Navigator/Yorodumi systems omit the EMD- prefix.

Related info.:Q: What is EMD? / ID/Accession-code notation in Yorodumi/EM Navigator

External links:EMDB Accession Codes are Changing Soon! / Contact to PDBj

+
Jul 12, 2017. Major update of PDB

Major update of PDB

  • wwPDB released updated PDB data conforming to the new PDBx/mmCIF dictionary.
  • This is a major update changing the version number from 4 to 5, and with Remediation, in which all the entries are updated.
  • In this update, many items about electron microscopy experimental information are reorganized (e.g. em_software).
  • Now, EM Navigator and Yorodumi are based on the updated data.

External links:wwPDB Remediation / Enriched Model Files Conforming to OneDep Data Standards Now Available in the PDB FTP Archive

-
Yorodumi Papers

Database of articles cited by EMDB/PDB/SASBDB data

  • Database of articles cited by EMDB, PDB, and SASBDB entries
  • Using PubMed data

Related info.:EMDB / PDB / SASBDB / Yorodumi / EMN Papers / Changes in new EM Navigator and Yorodumi

Read more