[English] 日本語
Yorodumi- EMDB-72176: Porcine thyroglobulin encapsulated in an MS2-nanocrate: MS2nc@Tg -
+
Open data
-
Basic information
| Entry | ![]() | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Title | Porcine thyroglobulin encapsulated in an MS2-nanocrate: MS2nc@Tg | ||||||||||||
Map data | map sharp | ||||||||||||
Sample |
| ||||||||||||
Keywords | Bacteriophage / VLP / MS2 / nanocrate / METAL BINDING PROTEIN | ||||||||||||
| Biological species | ![]() | ||||||||||||
| Method | single particle reconstruction / cryo EM / Resolution: 2.92 Å | ||||||||||||
Authors | Kopylov M / Bobe D / Jenkins MC / Zimanyi CM | ||||||||||||
| Funding support | United States, 3 items
| ||||||||||||
Citation | Journal: Nat Methods / Year: 2026Title: Overcoming air-water interface-induced artifacts in cryo-EM with protein nanocrates. Authors: Matthew C Jenkins / Daija Bobe / Jake D Johnston / Jonah Cheung / Akira Karasawa / Christina M Zimanyi / Ömer Dermanci / Collin T McManus / M G Finn / Alex de Marco / Mykhailo Kopylov / ![]() Abstract: Contact with the air-water interface can bias the orientation of macromolecules during cryo-electron microscopy sample preparation, leading to uneven sample distribution, preferred orientation and ...Contact with the air-water interface can bias the orientation of macromolecules during cryo-electron microscopy sample preparation, leading to uneven sample distribution, preferred orientation and damage to the molecules of interest. To prevent this, we describe a method to encapsulate target proteins within highly hydrophilic, structurally homogeneous and stable protein shells, which we refer to as 'nanocrates' for this purpose. Here we describe the packaging, data acquisition and reconstruction of three proof-of-principle examples, each illuminating a different aspect of the method: apoferritin (demonstrating high-resolution), thyroglobulin (solving a known preferred orientation problem) and 7,8-dihydroneopterin aldolase (a structure previously uncharacterized by cryo-electron microscopy). | ||||||||||||
| History |
|
-
Structure visualization
| Supplemental images |
|---|
-
Downloads & links
-EMDB archive
| Map data | emd_72176.map.gz | 398.1 MB | EMDB map data format | |
|---|---|---|---|---|
| Header (meta data) | emd-72176-v30.xml emd-72176.xml | 19.9 KB 19.9 KB | Display Display | EMDB header |
| FSC (resolution estimation) | emd_72176_fsc.xml | 15.8 KB | Display | FSC data file |
| Images | emd_72176.png | 50.3 KB | ||
| Masks | emd_72176_msk_1.map | 421.9 MB | Mask map | |
| Filedesc metadata | emd-72176.cif.gz | 4.9 KB | ||
| Others | emd_72176_additional_1.map.gz emd_72176_half_map_1.map.gz emd_72176_half_map_2.map.gz | 209.3 MB 391 MB 391 MB | ||
| Archive directory | https://data.pdbj.org/pub/emdb/structures/EMD-72176 ftp://data.pdbj.org/pub/emdb/structures/EMD-72176 | HTTPS FTP |
-Related structure data
-
Links
| EMDB pages | EMDB (EBI/PDBe) / EMDataResource |
|---|
-
Map
| File | Download / File: emd_72176.map.gz / Format: CCP4 / Size: 421.9 MB / Type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES) | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Annotation | map sharp | ||||||||||||||||||||||||||||||||||||
| Projections & slices | Image control
Images are generated by Spider. | ||||||||||||||||||||||||||||||||||||
| Voxel size | X=Y=Z: 0.826 Å | ||||||||||||||||||||||||||||||||||||
| Density |
| ||||||||||||||||||||||||||||||||||||
| Symmetry | Space group: 1 | ||||||||||||||||||||||||||||||||||||
| Details | EMDB XML:
|
-Supplemental data
-Mask #1
| File | emd_72176_msk_1.map | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Projections & Slices |
| ||||||||||||
| Density Histograms |
-Additional map: map unsharpened
| File | emd_72176_additional_1.map | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Annotation | map unsharpened | ||||||||||||
| Projections & Slices |
| ||||||||||||
| Density Histograms |
-Half map: halfmapB
| File | emd_72176_half_map_1.map | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Annotation | halfmapB | ||||||||||||
| Projections & Slices |
| ||||||||||||
| Density Histograms |
-Half map: halfmapA
| File | emd_72176_half_map_2.map | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Annotation | halfmapA | ||||||||||||
| Projections & Slices |
| ||||||||||||
| Density Histograms |
-
Sample components
-Entire : Porcine Thyroglobulin
| Entire | Name: Porcine Thyroglobulin |
|---|---|
| Components |
|
-Supramolecule #1: Porcine Thyroglobulin
| Supramolecule | Name: Porcine Thyroglobulin / type: complex / ID: 1 / Parent: 0 / Macromolecule list: #1 / Details: Porcine thyroglobulin from Sigma: T1126-500MG |
|---|---|
| Source (natural) | Organism: ![]() |
-Experimental details
-Structure determination
| Method | cryo EM |
|---|---|
Processing | single particle reconstruction |
| Aggregation state | particle |
-
Sample preparation
| Buffer | pH: 8.5 / Details: 50 mM Tris, 150 mM NaCl, pH 7.6 |
|---|---|
| Grid | Model: UltrAuFoil R1.2/1.3 / Material: GOLD / Mesh: 300 / Support film - Material: GOLD / Support film - topology: HOLEY / Pretreatment - Type: PLASMA CLEANING / Pretreatment - Time: 7 sec. |
| Vitrification | Cryogen name: ETHANE / Instrument: FEI VITROBOT MARK IV |
-
Electron microscopy
| Microscope | TFS KRIOS |
|---|---|
| Specialist optics | Energy filter - Name: GIF Bioquantum / Energy filter - Slit width: 20 eV |
| Image recording | Film or detector model: GATAN K3 BIOQUANTUM (6k x 4k) / Number grids imaged: 1 / Number real images: 9194 / Average exposure time: 1.25 sec. / Average electron dose: 40.77 e/Å2 |
| Electron beam | Acceleration voltage: 300 kV / Electron source: FIELD EMISSION GUN |
| Electron optics | C2 aperture diameter: 100.0 µm / Illumination mode: FLOOD BEAM / Imaging mode: BRIGHT FIELD / Cs: 2.7 mm / Nominal defocus max: 2.0 µm / Nominal defocus min: 0.7000000000000001 µm / Nominal magnification: 105000 |
| Sample stage | Specimen holder model: FEI TITAN KRIOS AUTOGRID HOLDER / Cooling holder cryogen: NITROGEN |
| Experimental equipment | ![]() Model: Titan Krios / Image courtesy: FEI Company |
Movie
Controller
About Yorodumi



Keywords
Authors
United States, 3 items
Citation





Z (Sec.)
Y (Row.)
X (Col.)




















































Processing
FIELD EMISSION GUN

