[English] 日本語
Yorodumi Papers
- Database of articles cited by EMDB/PDB/SASBDB data -

+
Search query

Keywords
Structure methods
Author
Journal
IF

-
Structure paper

TitleAbout the alignment and 3D reconstruction of sparse cryo-scanning transmission electron tomography datasets.
Journal, issue, pagesUltramicroscopy, Vol. 284, Page 114362, Year 2026
Publish dateApr 6, 2026
AuthorsSylvain Trépout /
PubMed AbstractIn electron microscopy, sparse imaging consists in the collection of a limited subset of the image pixels, which can be used to reduce electron beam damage. Scanning transmission electron microscopy ...In electron microscopy, sparse imaging consists in the collection of a limited subset of the image pixels, which can be used to reduce electron beam damage. Scanning transmission electron microscopy (STEM) is particularly adapted to sparse imaging owing to the scanning nature of the method, scan patterns can be designed where fewer sample locations are targeted. However, since some of the pixels are not scanned, there is an inherent loss of information. Several algorithms were developed to reconstruct missing pixels with high fidelity. Whereas sparse imaging and missing pixel reconstruction in 2D experiments are mature methods, the application of sparse imaging in 3D scanning transmission electron tomography (STET) is rare and still under development. The main difficulty encountered in tomography studies is the tilt-series alignment, which must be accurate to ensure high-quality 3D reconstruction. Because sparse images contain only a certain portion of the original information, the images constituting sparse tilt-series might not share enough mutual information to guarantee an accurate alignment, even after missing pixel reconstruction. This work presents for the first time a thorough analysis of the fiducial alignment and reconstruction of sparse (cryo-)STET tilt-series. Furthermore, the limits of sparse imaging are explored to estimate the minimum amount of information required to obtain good-quality 3D reconstructions. The use of a cryo-fixed biological sample is motivated by the fact that cryo-samples are typical highly beam-sensitive samples, and that the intricate nature and structure complexity of biological samples place them among the most difficult ones to reconstruct with high details.
External linksUltramicroscopy / PubMed:41946304
MethodsEM (tomography)
Structure data

EMDB-71629: Comparison of fully-sampled and sparse cryo-STEM tomography 3D reconstructions
Method: EM (tomography)

Source
  • Escherichia coli (E. coli)

+
About Yorodumi Papers

-
News

-
Feb 9, 2022. New format data for meta-information of EMDB entries

New format data for meta-information of EMDB entries

  • Version 3 of the EMDB header file is now the official format.
  • The previous official version 1.9 will be removed from the archive.

Related info.:EMDB header

External links:wwPDB to switch to version 3 of the EMDB data model

-
Aug 12, 2020. Covid-19 info

Covid-19 info

URL: https://pdbj.org/emnavi/covid19.php

New page: Covid-19 featured information page in EM Navigator.

Related info.:Covid-19 info / Mar 5, 2020. Novel coronavirus structure data

+
Mar 5, 2020. Novel coronavirus structure data

Novel coronavirus structure data

Related info.:Yorodumi Speices / Aug 12, 2020. Covid-19 info

External links:COVID-19 featured content - PDBj / Molecule of the Month (242):Coronavirus Proteases

+
Jan 31, 2019. EMDB accession codes are about to change! (news from PDBe EMDB page)

EMDB accession codes are about to change! (news from PDBe EMDB page)

  • The allocation of 4 digits for EMDB accession codes will soon come to an end. Whilst these codes will remain in use, new EMDB accession codes will include an additional digit and will expand incrementally as the available range of codes is exhausted. The current 4-digit format prefixed with “EMD-” (i.e. EMD-XXXX) will advance to a 5-digit format (i.e. EMD-XXXXX), and so on. It is currently estimated that the 4-digit codes will be depleted around Spring 2019, at which point the 5-digit format will come into force.
  • The EM Navigator/Yorodumi systems omit the EMD- prefix.

Related info.:Q: What is EMD? / ID/Accession-code notation in Yorodumi/EM Navigator

External links:EMDB Accession Codes are Changing Soon! / Contact to PDBj

+
Jul 12, 2017. Major update of PDB

Major update of PDB

  • wwPDB released updated PDB data conforming to the new PDBx/mmCIF dictionary.
  • This is a major update changing the version number from 4 to 5, and with Remediation, in which all the entries are updated.
  • In this update, many items about electron microscopy experimental information are reorganized (e.g. em_software).
  • Now, EM Navigator and Yorodumi are based on the updated data.

External links:wwPDB Remediation / Enriched Model Files Conforming to OneDep Data Standards Now Available in the PDB FTP Archive

-
Yorodumi Papers

Database of articles cited by EMDB/PDB/SASBDB data

  • Database of articles cited by EMDB, PDB, and SASBDB entries
  • Using PubMed data

Related info.:EMDB / PDB / SASBDB / Yorodumi / EMN Papers / Changes in new EM Navigator and Yorodumi

Read more