Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5L3C

Human LSD1/CoREST: LSD1 E379K mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-12-06
DetectorDECTRIS PILATUS 300K
Wavelength(s)0.976256
Spacegroup nameI 2 2 2
Unit cell lengths120.368, 180.389, 235.422
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.000 - 3.310
R-factor0.19906
Rwork0.199
R-free0.22324
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)2v1d
RMSD bond length0.010
RMSD bond angle1.398
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0135)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.450
High resolution limit [Å]3.3003.300
Rmerge0.1300.800
Number of reflections38276
<I/σ(I)>8.51.2
Completeness [%]99.099
Redundancy3.83.9
CC(1/2)0.990
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5298Tartrate 1-1.4 M, ADA 100 mM pH 6.5

218500

건을2024-04-17부터공개중