Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4PHR

Domain of unknown function 1792 (DUF1792) with manganese

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2011-03-07
DetectorMAR CCD 165 mm
Wavelength(s)1.0000
Spacegroup nameC 1 2 1
Unit cell lengths71.474, 45.409, 78.782
Unit cell angles90.00, 109.74, 90.00
Refinement procedure
Resolution37.640 - 1.340
R-factor0.149
Rwork0.147
R-free0.18800
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle1.153
Refinement softwarePHENIX ((PHENIX.REFINE: 1.7.1_743))
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]1.340
Number of reflections52820
<I/σ(I)>52.6
Completeness [%]98.6
Redundancy5.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293Tris buffer, PEG 1500, NaAcetate

218853

数据于2024-04-24公开中