Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3QKR

Mre11 Rad50 binding domain bound to Rad50

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL11-1
Synchrotron siteSSRL
BeamlineBL11-1
Temperature [K]100
Detector technologyCCD
Collection date2003-05-01
DetectorADSC QUANTUM 315
Spacegroup nameP 61
Unit cell lengths116.041, 116.041, 109.853
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.000 - 3.400
R-factor0.21432
Rwork0.211
R-free0.27444
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ii8
RMSD bond length0.006
RMSD bond angle1.031
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]100.0003.488
High resolution limit [Å]3.4003.400
Rmerge0.1090.335
Number of reflections10679
<I/σ(I)>14.22
Completeness [%]91.556.39
Redundancy6.62.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293100 mM Tris, 200-300 mM lithium sulfate, 12-13% PEG3350, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

數據於2024-04-24公開中