Loading
PDBj
メニューPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2I1J

Moesin from Spodoptera frugiperda at 2.1 angstroms resolution

Experimental procedure
実験手法SINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]112
Detector technologyCCD
DetectorADSC QUANTUM 210
Wavelength(s)1.000
Spacegroup nameH 3 2
格子定数 [Å]123.739, 123.739, 283.183
格子定数 [度]90.00, 90.00, 120.00
精密化法
残基50.000 - 2.100
R因子0.176
Rwork0.179
R-free0.21500
Structure solution methodMOLECULAR REPLACEMENT
結合長の平均二乗偏差(RMSD) [Å]0.010
結合角の平均二乗偏差(RMSD) [度]1.114
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.2.0019)
Quality characteristics
 Overall
分解能 [Å] (低)42.720
分解能 [Å] (高)2.000
独立反射数43611
結晶化条件
結晶ID方法pH温度溶液条件
1VAPOR DIFFUSION, HANGING DROP8277100 mM HEPES pH 8.0, 15% PEG 8000, 50 mM phosphoserine, 800 mM NaCl, 1 M urea, VAPOR DIFFUSION, HANGING DROP, temperature 277K

218853

件を2024-04-24に公開中

PDB statisticsPDBj update infoContact PDBjnumon