Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1W0Y

tf7a_3771 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM1A
Synchrotron siteESRF
BeamlineBM1A
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date1997-01-30
DetectorMARRESEARCH
Spacegroup nameP 21 21 21
Unit cell lengths71.338, 82.378, 123.963
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.990 - 2.500
Rwork0.199
R-free0.25800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1dan
RMSD bond length0.010
RMSD bond angle1.700
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareAMoRE
Refinement softwareCNX (2002)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0002.580
High resolution limit [Å]2.4602.460
Rmerge0.1300.390
Number of reflections85076
Completeness [%]87.850.3
Redundancy3.272.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
15.5pH 5.50

218500

數據於2024-04-17公開中

PDB statisticsPDBj update infoContact PDBjnumon