1RGQ
M9A HCV Protease complex with pentapeptide keto-amide inhibitor
Experimental procedure
実験手法 | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 1999-01-08 |
Detector | MARRESEARCH |
Wavelength(s) | 1.54 |
Spacegroup name | H 3 2 |
格子定数 [Å] | 226.385, 226.385, 76.864 |
格子定数 [度] | 90.00, 90.00, 120.00 |
精密化法
残基 | 34.120 - 2.900 |
Rwork | 0.279 |
R-free | 0.31200 |
Structure solution method | MOLECULAR REPLACEMENT |
結合長の平均二乗偏差(RMSD) [Å] | 0.013 |
結合角の平均二乗偏差(RMSD) [度] | 1.700 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | CNX |
Refinement software | CNX |
Quality characteristics
Overall | Outer shell | |
分解能 [Å] (低) | 34.120 | 3.000 |
分解能 [Å] (高) | 2.900 | 2.900 |
独立反射数 | 16212 | |
完全性 [%] | 96.7 | 100 |
結晶化条件
結晶ID | 方法 | pH | 温度 | 溶液条件 |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 0.2M N/KPO4, 2.0M NaCl, 10mM MES, 15% glycerol, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |