Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1J8M

Signal Recognition Particle conserved GTPase domain from A. ambivalens

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Detector technologyIMAGE PLATE
DetectorMARRESEARCH
Spacegroup nameC 2 2 21
Unit cell lengths64.866, 128.020, 72.004
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.000 - 2.000
R-factor0.21916
Rwork0.216
R-free0.27002
RMSD bond length0.011

*

RMSD bond angle1.100

*

Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Refinement softwareREFMAC
Data quality characteristics
 Overall
Low resolution limit [Å]40.000
High resolution limit [Å]2.000
Rmerge0.051

*

Total number of observations451808

*

Number of reflections20842
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

20

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein8 (mg/ml)
21reservoiracetate100 (mM)
31reservoircalcium acetate100 (mM)
41reservoirPEG800018 (%)

218853

건을2024-04-24부터공개중

PDB statisticsPDBj update infoContact PDBjnumon