1AJG

CARBONMONOXY MYOGLOBIN AT 40 K

Experimental procedure
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X26C
Synchrotron siteNSLS
BeamlineX26C
Temperature [K]40
Detector technologyIMAGE PLATE
Collection date1993-06-30
DetectorFUJI
Spacegroup nameP 1 21 1
Unit cell lengths63.430, 30.430, 34.120
Unit cell angles90.00, 105.67, 90.00
Refinement procedure
Resolution10.000 - 1.690
R-factor0.171
Rwork0.171
R-free0.23800
Structure solution methodDIFFERENCE FOURIER
Starting model (for MR)1mbo
RMSD bond length0.013
RMSD bond angle19.000

*

Data reduction softwareDENZO
Data scaling softwareCCP4
Phasing softwareX-PLOR
Refinement softwareX-PLOR
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]27.5001.770
High resolution limit [Å]1.6901.690
Rmerge0.0490.147
Number of reflections13483
<I/σ(I)>10.75.1
Completeness [%]95.083.5
Redundancy32.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1unknown

*

6AS DESCRIBED IN KENDREW,J.C. AND PARRISH,R.G., PROC. ROY. SOC. A (LONDON) 238, 305-324 (1956), pH 6.0

218500

건을2024-04-17부터공개중