Beam | Instrument name: Australian Synchrotron SAXS/WAXS / City: Melbourne / 国: Australia / Type of source: X-ray synchrotron Synchrotron / Wavelength: 0.1078 Å / Dist. spec. to detc.: 2.038 mm |
---|
Detector | Name: Dectris/Pilatus3 S 2M / Pixsize x: 172 mm |
---|
Scan | Title: Interleukin 11, N-terminally truncated / Measurement date: Jun 8, 2019 / Cell temperature: 20 °C / Exposure time: 1 sec. / Number of frames: 8 / Unit: 1/A / |
---|
Distance distribution function P(R) | Sofotware P(R): GNOM 5.0 / Number of points: 458 / | Min | Max |
---|
Q | 0.0103239 | 0.45859 |
---|
P(R) point | 1 | 458 |
---|
R | 0 | 54 |
---|
|
---|
Result | Type of curve: sec / | Experimental | Porod |
---|
MW | 16.3 kDa | 13.6 kDa |
---|
Volume | - | 21.7 nm3 |
---|
| P(R) | Guinier | Guinier error |
---|
Forward scattering, I0 | 0.006139 | 0.006122 | 2.4E-5 |
---|
Radius of gyration, Rg | 1.76 nm | 1.743 nm | 0.011 |
---|
| Min | Max |
---|
D | - | 5.4 |
---|
Guinier point | 4 | 70 |
---|
|
---|