EntrySummary Database / ID EM DATA BANK (EMDB) / 2119 Title Cryo-electron tomography averaged map of microtubule doublet 1 in the proximal region of Chlamydomonas axoneme Map Reconstruction of outer doublet 1 of the Chlamydomonas axoneme in the proximal region. Sample Outer doublet 1 of Chlamydomonas axoneme in the proximal region Keywords axoneme , dynein , Chlamydomonas , microtubule doubletAuthors Bui KH , Yagi T , Yamamoto R , Kamiya R , Ishikawa T Date Deposition : 2012-06-11, Header release : 2012-06-14, Map release : 2012-09-12, Last update : 2012-09-26EMDB Sites EMDB @PDBe (EU) , EMDB @RCSB (USA)Structure Visualization Movies Play Pause Small Medium LargeX OffMovie Page #1 #2 #1 : Surface view with section colored by density value, Surface level: 0.8, Made by UCSF CHIMERA
#2 : Surface view colored by cylindrical radius, Surface level: 0.8, Made by UCSF CHIMERA
Supplemental images
Structure viewers Yorodumi , Launch PeppeR (About PeppeR) , Volume viewer (RCSB , PDBe )Related Structure Data Related Entries
Cite : data citing same article
Similar strucutres (beta)
List of similar structure data about Omokage system
ArticleCitation - Primary Article J. Cell Biol. , Vol. 198, Issue 5, Page 913-25, Year 2012Title Polarity and asymmetry in the arrangement of dynein and related structures in the Chlamydomonas axoneme. Authors Khanh Huy Bui , Toshiki Yagi , Ryosuke Yamamoto , Ritsu Kamiya , Takashi Ishikawa Laboratory of Biomolecular Research, Paul Scherrer Institute, CH-5232 Villigen, Switzerland.Keywords Chlamydomonas (chemistry), Dyneins (chemistry, 3.6.4.2 ), Flagella (chemistry), Microtubules (chemistry), Plant Cells (chemistry), Plant Proteins (chemistry)Links DOI: 10.1083/jcb.201201120 , PubMed: 22945936 , PMC: PMC3432765
ExperimentSample Preparation Specimen Conc 2 mg/ml Specimen Support Details 300 mesh Quantifoil Holey Carbon copper grid R2/1 Buffer Details : 30 mM Hepes, pH 7.4, 5 mM MgSO4, 1 mM DTT, 0.5 mM EDTA, 25 mM KCl, and 0.5% (wt/vol) polyethylene glycol (MW 20,000) pH : 7.4 Vitrification Method Offset -3, blot 3 seconds, drain time 0 second Cryogen Name ETHANE Humidity 90 Instrument FEI VITROBOT MARK II Temperature 110 Kelvin Imaging Microscope FEI TECNAI 20 Date 26-NOV-2010 Electron Gun Electron Source FIELD EMISSION GUN Accelerating Voltage 200 kV Electron Dose 60 e/A**2 Illumination Mode FLOOD BEAM Lens Magnification Nominal : 27500, Calibrated : 19303Nominal Cs 2 mm Imaging Mode BRIGHT FIELD Defocus 4000 nm - 6000 nm Energy Filter Energy Filter : Gatan Tridem , Energy Window : 0-20 eVSpecimen Holder Holder Gatan 626, liquid nitrogen cooled Model GATAN LIQUID NITROGEN Tilt Angle -60 degrees - 60 degrees Temperature 98 K ( 93 - 118 K) Camera Detector Gatan Ultrascan 1000 FT CCD Image Acquisition Number of Digital Images 499 Quant Bit Number 16